Watertight Fiberglass Turbine Sump PackagesAvailable in both single and double wall configurations. Each package includes a patented watertight multiport sump shield. Our octagonal base sumps are a two piece design eliminating the need to work in a confined space during installation. Eight flat panels are molded into the bottom section to provide 90° pipe entries. Most single wall models are available with or without bottom for various mounting options. Double wall models are only available for mounting to tank collar. |
| PART | WALL TYPE | RISER DIA. | MIN. MANHOLE SIZE | BOTTOM | 13" SPILL CONTAINER OPENINGS | 8" OPENINGS | SEAM KITS RECOMM. |
|---|---|---|---|---|---|---|---|
| M(X)4236-2/1-RC-5 | Single | 42 | 36 | No | 2 | 1 | 2 |
Medium bury is 48" overall height and deep bury is 72" overall height.
Seam kits are not included. See bottom of page for part number.
| PART | WALL TYPE | OCT. BASE DIA. | MIN. MANHOLE SIZE | RISER DIA. | BOTTOM | 13” SPILL CONT. OPENINGS | 8” OPENINGS | SEAM KITS RECOMM. |
|---|---|---|---|---|---|---|---|---|
| M(X)4236-2/1-OC-S | Single | 42 | 36 | 39 | No | 2 | 1 | 2 |
| M(X)4236-2/1-OB-S | Single | 42 | 36 | 39 | Yes | 2 | 1 | 1 |
| M(X)4236-2/1-OC-H | Double | 42 | 36 | 39 | No | 2 | 1 | 4 |
| M(X)4236-2/1-OC-V | Double | 42 | 36 | 39 | No | 2 | 1 | 4 |
Medium bury is 48” overall height and deep bury is 68” overall height.
Seam kits are not included. See bottom of page for part number.
| PART | WALL TYPE | OCT. BASE DIA. | MIN. MANHOLE SIZE | RISER DIA. | BOTTOM | 13” SPILL CONT. OPENINGS | 8” OPENINGS | SEAM KITS RECOMM. |
|---|---|---|---|---|---|---|---|---|
| M(X)4836-2/1-OC-S | Single | 48 | 36 | 42 | No | 2 | 1 | 3 |
| M(X)4836-2/1-OB-S | Single | 48 | 36 | 42 | Yes | 2 | 1 | 2 |
| M(X)4842-2/1-OC-S | Single | 48 | 42 | 42 | No | 2 | 1 | 3 |
| M(X)4842-2/1-OB-S | Single | 48 | 42 | 42 | Yes | 2 | 1 | 2 |
| M(X)4836-2/1-OC-H | Double | 48 | 36 | 42 | No | 2 | 1 | 4 |
| M(X)4836-2/1-OC-V | Double | 48 | 36 | 42 | No | 2 | 1 | 4 |
| M(X)4842-2/1-OC-H | Double | 48 | 42 | 42 | No | 2 | 1 | 4 |
| M(X)4842-2/1-OC-V | Double | 48 | 42 | 42 | No | 2 | 1 | 4 |
Medium bury is 45” overall height and deep bury is 66” overall height.
Seam kits are not included. See bottom of page for part number.
Packages include watertight sump shield, sump reducer and
appropriate size and quantity neoprene boots and 316 SS clamps.
Replace (X) in part number with burial depth available:
| PART | DESCRIPTION |
|---|---|
| FG-SEAMKIT | Includes matte, resin, putty and catalyst for one fi berglass seam single or double wall. Note: Double wall applications may require 2 seam kits per seam. |
| PART | WALL TYPE | OCT. BASE DIA. | MIN. MANHOLE SIZE | RISER DIA. | BOTTOM | 13” SPILL CONT. OPENINGS | 8” OPENINGS | SEAM KITS RECOMM. |
|---|---|---|---|---|---|---|---|---|
| M(X)4236-1/0-OC-S | Single | 42 | 36 | 39 | No | 1 | 0 | 2 |
| M(X)4236-1/0-OB-S | Single | 42 | 36 | 39 | Yes | 1 | 0 | 1 |
| M(X)4236-1/0-OC-H | Double | 42 | 36 | 39 | No | 1 | 0 | 4 |
| M(X)4236-1/0-OC-V | Double | 42 | 36 | 39 | No | 1 | 0 | 4 |
| PART | WALL TYPE | OCT. BASE DIA. | MIN. MANHOLE SIZE | RISER DIA. | BOTTOM | 13” SPILL CONT. OPENINGS | 8” OPENINGS | SEAM KITS RECOMM. |
|---|---|---|---|---|---|---|---|---|
| M(X)4836-1/0-OC-S | Single | 48 | 36 | 42 | No | 1 | 0 | 3 |
| M(X)4836-1/0-OB-S | Single | 48 | 36 | 42 | Yes | 1 | 0 | 2 |
| M(X)4842-1/0-OC-S | Single | 48 | 42 | 42 | No | 1 | 0 | 3 |
| M(X)4842-1/0-OB-S | Single | 48 | 42 | 42 | Yes | 1 | 0 | 2 |
| M(X)4836-1/0-OC-H | Double | 48 | 36 | 42 | No | 1 | 0 | 4 |
| M(X)4836-1/0-OC-V | Double | 48 | 36 | 42 | No | 1 | 0 | 4 |
| M(X)4842-1/0-OC-H | Double | 48 | 42 | 42 | No | 1 | 0 | 4 |
| M(X)4842-1/0-OC-V | Double | 48 | 42 | 42 | No | 1 | 0 | 4 |
Medium bury is 45” overall height and deep bury is 66” overall height. Seam kits are not included. See bottom of page for part number. Packages include watertight sump shield, sump reducer and appropriate size and quantity neoprene boots and 316 SS clamps. Replace (X) in part number with burial depth available:
| PART | DESCRIPTION |
|---|---|
| FG-SEAMKIT | Includes matte, resin, putty and catalyst for one fi berglass seam single or double wall. Note: Double wall applications may require 2 seam kits per seam. |
| PART | WALL TYPE | OCT. BASE DIA. | MIN. MANHOLE SIZE | RISER DIA. | BOTTOM | 13” SPILL CONT. OPENINGS | 8” OPENINGS | SEAM KITS RECOMM. |
|---|---|---|---|---|---|---|---|---|
| M(X)4842-4/0-OC-S | Single | 48 | 42 | 42 | No | 4 | 1 | 3 |
| M(X)4842-4/0-OB-S | Single | 48 | 42 | 42 | Yes | 4 | 1 | 2 |
| M(X)4842-4/0-OC-H | Double | 48 | 42 | 42 | No | 4 | 1 | 4 |
| M(X)4842-4/0-OC-V | Double | 48 | 42 | 42 | No | 4 | 1 | 4 |
Medium bury is 45” overall height and deep bury is 66” overall height. Seam kits are not included. See bottom of page for part number. Packages include watertight sump shield, sump reducer and appropriate size and quantity neoprene boots and 316 SS clamps. Replace (X) in part number with burial depth available:
| PART | DESCRIPTION |
|---|---|
| FG-SEAMKIT | Includes matte, resin, putty and catalyst for one fi berglass seam single or double wall. Note: Double wall applications may require 2 seam kits per seam. |